8. Check VIAS Control Solenoid Valve Output Signal Circuit For Open And Short
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 27 and terminal 2.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK: GO TO 9.
NG: Repair open circuit or short to ground or short to power in harness or connectors.