LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2006 >> M35 Base >> Repair and Diagnosis >> Body & Frame >> Seats >> Automatic Drive Positioner >> Terminals and Reference Values for Automatic Drive Positioner Control Unit
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Terminals and Reference Values for Automatic Drive Positioner Control Unit

AUTOMATIC DRIVE POSITIONER CONTROL UNIT TERMINALS AND REFERENCE VALUE

Terminal Wire color Item Condition Voltage (V) (Approx)
1 Y Tilt switch UP signal Tilt switch is UP operation 0
Other than above 5
5 L/R Mirror sensor (RH vertical) signal When mirror motor RH is UP or DOWN operation Changes between 4.2 (close to perk) 0.5 (close to valley)
6 LG Mirror sensor (LH vertical) signal When mirror motor LH is UP or DOWN operation Changes between 4.2 (close to perk) 0.5 (close to valley)
7 L Tilt sensor signal Tilt position: Top 1
Tilt position: Bottom 3.8
9 LG Memory switch 1 signal Memory switch 1 ON 0
Other than above 5
10 O UART LINE (TX) Tilt switch operated
G04131129
11 R Telescopic switch forward signal When telescopic switch is forward operation 0
Other than above 5
12 R/G Memory switch indictor 1 signal When illuminate indictor 1 1
Other than above Battery voltage
13 P Memory switch indictor 2 signal When illuminate indictor 2 1
Other than above Battery voltage
14 L Mirror motor RH UP signal When mirror motor RH UP operation Battery voltage
Other than above 0
15 G Mirror motor RH LEFT signal When mirror motor RH LEFT operation Battery voltage
Other than above 0
16 W/L Mirror motor LH DOWN signal When mirror motor LH DOWN operation Battery voltage
Other than above 0
Mirror motor LH RIGHT signal When mirror motor LH RIGHT operation Battery voltage
Other than above 0
17 LG Tilt switch DOWN signal When tilt switch is DOWN position 0
Other than above 5
21 SB Mirror sensor (RH horizontal) signal When mirror motor RH is LEFT or RIGHT operation Changes between 3.5 (close to left edge) 0.5 (close to right edge)
22 O/L Mirror sensor (LH horizontal) signal When mirror motor LH is LEFT or RIGHT operation Changes between 0.5 (close to left edge) 3.5 (close to right edge)
23 GR Telescopic sensor input Telescopic position: Top 4.6
Telescopic position: Bottom 0.4
24 BR/W Set switch signal Set switch ON 0
Other than above 5
25 LG/B Memory switch 2 signal Memory switch 2 ON 0
Other than above 5
26 P UART LINE (RX) Tilt switch is operated
G04131129
27 W Telescopic switch backward signal Telescopic switch turned to backward 0
Other than above 5
30 GR Mirror motor RH DOWN signal When mirror motor RH DOWN operation Battery voltage
Other than above 0
Mirror motor RH RIGHT signal When mirror motor RH RIGHT operation Battery voltage
Other than above 0
31 BR Mirror motor LH UP signal When mirror motor LH UP operation Battery voltage
Other than above 0
32 V Mirror motor LH LEFT signal When mirror motor LH LEFT operation Battery voltage
Other than above 0
33 W Sensor power supply - 5
34 R Power source (Fuse) - Battery voltage
35 LG Tilt motor UP signal Tilt switch is UP operation Battery voltage
Other than above 0
36 P Telescopic motor forward signal Telescopic switch is forward operation Battery voltage
Other than above 0
39 L Power source (C/B) - Battery voltage
40 B Ground - 0
41 Y Sensor ground - 0
42 G Tilt motor DOWN signal Tilt switch is DOWN operation Battery voltage
Other than above 0
44 G Telescopic motor backward signal Telescopic switch is backward operation Battery voltage
Other than above 0
48 B Ground - 0