Terminal and Reference Value for Front Power Window Switch (Passenger Side)
TERMINAL AND REFERENCE VALUE CHART FOR FRONT POWER WINDOW SWITCH (PASSENGER SIDE)
| Terminal | Wire color | Item | Signal Input/Output | Condition | Voltage [V] (Approx.) |
|---|---|---|---|---|---|
| 3 | SB | Limit switch and encoder ground | Input | - | 0 |
| 4 | R | Encoder power supply | Output | When ignition switch ON or power window timer operates | 10 |
| 8 | L | Front passenger side power window motor UP signal | Output | When power window motor is UP at operated. | Battery voltage |
| 9 | G | Front passenger side power window motor DOWN signal | Output | When power window motor is DOWN at operated. | Battery voltage |
| 10 | W | Battery power supply | Input | - | Battery voltage |
| 11 | B | Ground | - | - | 0 |
| 12 | PU | Encoder pulse signal | Input | When power window motor operates. | |
| 15 | GY | Limit switch signal | Input | Passenger side door window is between fully-open and just before fully-closed position (ON) | 0 |
| Passenger side door window is between just before fully-closed position and fully-closed position (OFF) | 5 | ||||
| 16 | Y | Power window serial link | Input/Output | IGN SW ON or power window timer operating. |