Terminals and Reference Value for ICC Sensor Integrated Unit
CONNECTOR TERMINAL VOLTAGE SPECIFICATION
| Terminals (Wire color) | Item | Condition | Voltage (V) | ||
|---|---|---|---|---|---|
| + | - | Ignition switch | Operation | ||
| 1 (G/B) | Ground | Ignition switch ON or START | ON | - | Battery voltage |
| 2 (G) | Stop lamp drive output signal | ON | At "STOP LAMP" test on "ACTIVE TEST" | Approx.12 | |
| - | Approx. 0 | ||||
| 3 (L) | CAN-H | - | - | - | |
| 4 (B/Y) | Ground | ON | - | Approx. 0 | |
| 6 (P) | CAN-L | - | - | - | |