Diagnostic Procedure
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect Intelligent Key unit and push-button ignition switch connector.
- Check continuity between Intelligent Key unit connector and push-button ignition switch connector.TERMINAL CONTINUITY CHART
A B Continuity Intelligent Key unit connector Terminal Push-button ignition switch connector Terminal M32 39 M27 4 Yes - Check continuity between Intelligent Key unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Intelligent Key unit connector Terminal M32 39 No
OK or NG
OK: GO TO 2.
NG: Repair or replace harness.
- CHECK PUSH-BUTTON IGNITION SWITCH
Check push-button ignition switch.
PUSH-BUTTON IGNITION SWITCH SPECIFICATIONTerminal Push-button ignition switch condition Continuity Push-button ignition switch 1 4 Pushed Yes Released No OK or NG
OK: Check the condition of harness and connector. If it is OK, check the self-diagnosis results using CONSULT-II again.
NG: Replace push-button ignition switch.