Check Trunk Opener Request Switch
- CHECK TRUNK OPENER REQUEST SWITCH
With CONSULT-II
Check trunk opener request switch ("BD/TR REQ SW") in "DATA MONITOR" mode.
DATA MONITORMonitor item Condition BD/TR REQ SW Trunk opener request switch is pressed: ON Trunk opener request switch is released: OFF Without CONSULT-II
- Turn ignition switch OFF.
- Check voltage between Intelligent Key unit connector and ground.TERMINAL VOLTAGE CHART
Terminals Trunk lid opener request switch condition Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M33 61 Ground Pressed 0 Released 5
OK or NG
OK: Trunk opener request switch is OK.
NG: GO TO 2.
- CHECK TRUNK OPENER REQUEST SWITCH CIRCUIT
- Disconnect Intelligent Key unit and trunk opener request switch connector.
- Check continuity between Intelligent Key unit connector and trunk opener request switch connector.TERMINAL CONTINUITY CHART
A B Continuity Intelligent Key unit connector Terminal Trunk request switch connector Terminal M33 61 T107 1 Yes - Check continuity between Intelligent Key unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Intelligent Key unit connector Terminal M33 61 No
OK or NG
OK: GO TO 3.
NG: Repair or replace harness between Intelligent Key unit and trunk opener request switch.
- CHECK TRUNK OPENER REQUEST SWITCH OPERATION
Check trunk opener request switch.
TERMINAL CONTINUITY CHARTTerminal Trunk opener request switch condition Continuity Trunk opener request switch 1 2 Pressed Yes Released No OK or NG
OK: GO TO 4.
NG: Replace trunk opener request switch.
- CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUIT
Check continuity between trunk opener request switch connector and ground.
TERMINAL CONTINUITY CHARTTrunk opener request switch connector Terminal Ground Continuity T107 2 Yes OK or NG
OK: GO TO 5.
NG: Repair or replace trunk opener request switch ground circuit.
- CHECK INTELLIGENT KEY UNIT OUTPUT SIGNAL
- Connect Intelligent Key unit connector.
- Check voltage between Intelligent Key unit connector and ground.TERMINAL VOLTAGE CHART
Terminals Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M33 61 Ground 5
OK or NG
OK: Check the condition of harness and connector.
NG: Replace Intelligent Key unit.