LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2007 >> M35 Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Body, Lock & Security System >> Intelligent Key System >> Check Trunk Opener Request Switch
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Check Trunk Opener Request Switch

  1. CHECK TRUNK OPENER REQUEST SWITCH 

    With CONSULT-II 

    Check trunk opener request switch ("BD/TR REQ SW") in "DATA MONITOR" mode.

    DATA MONITOR

    Monitor item Condition
    BD/TR REQ SW Trunk opener request switch is pressed: ON
    Trunk opener request switch is released: OFF
    Fig 1: CONSULT-II Display - Data Monitor
    G04916828

    Without CONSULT-II 

    1. Turn ignition switch OFF.
    2. Check voltage between Intelligent Key unit connector and ground.
      TERMINAL VOLTAGE CHART

      Terminals Trunk lid opener request switch condition Voltage (V) (Approx.)
      (+) (-)
      Intelligent Key unit connector Terminal
      M33 61 Ground Pressed 0
      Released 5

    OK or NG 

    OK: Trunk opener request switch is OK.

    NG: GO TO 2.

    Fig 2: Checking Voltage Between Intelligent Key Unit Connector Terminal 61 And Ground
    G05212223
  2. CHECK TRUNK OPENER REQUEST SWITCH CIRCUIT 
    1. Disconnect Intelligent Key unit and trunk opener request switch connector.
    2. Check continuity between Intelligent Key unit connector and trunk opener request switch connector.
      TERMINAL CONTINUITY CHART

      A B Continuity
      Intelligent Key unit connector Terminal Trunk request switch connector Terminal
      M33 61 T107 1 Yes
    3. Check continuity between Intelligent Key unit connector and ground.
      TERMINAL CONTINUITY CHART

      A Ground Continuity
      Intelligent Key unit connector Terminal
      M33 61 No
      Fig 3: Checking Continuity Between Intelligent Key Unit Connector Terminal 61 And Ground
      G05212224

    OK or NG 

    OK: GO TO 3.

    NG: Repair or replace harness between Intelligent Key unit and trunk opener request switch.

  3. CHECK TRUNK OPENER REQUEST SWITCH OPERATION 

    Check trunk opener request switch.

    TERMINAL CONTINUITY CHART

    Terminal Trunk opener request switch condition Continuity
    Trunk opener request switch
    1 2 Pressed Yes
    Released No

    OK or NG 

    OK: GO TO 4.

    NG: Replace trunk opener request switch.

    Fig 4: Checking Trunk Opener Request Switch
    G05212225
  4. CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUIT 

    Check continuity between trunk opener request switch connector and ground.

    TERMINAL CONTINUITY CHART

    Trunk opener request switch connector Terminal Ground Continuity
    T107 2 Yes

    OK or NG 

    OK: GO TO 5.

    NG: Repair or replace trunk opener request switch ground circuit.

    Fig 5: Checking Continuity Between Trunk Opener Request Switch Connector Terminal 2 And Ground
    G05212226
  5. CHECK INTELLIGENT KEY UNIT OUTPUT SIGNAL 
    1. Connect Intelligent Key unit connector.
    2. Check voltage between Intelligent Key unit connector and ground.
      TERMINAL VOLTAGE CHART

      Terminals Voltage (V) (Approx.)
      (+) (-)
      Intelligent Key unit connector Terminal
      M33 61 Ground 5

    OK or NG 

    OK: Check the condition of harness and connector.

    NG: Replace Intelligent Key unit.

    Fig 6: Checking Voltage Between Intelligent Key Unit Connector Terminal 61 And Ground
    G05212223