Check Warning Chime Function
- CHECK WARNING CHIME INTO COMBINATION METER OPERATION
With CONSULT-II
- Check the operation with "INSIDE BUZZER" in the "ACTIVE TEST".
- Touch "TAKE OUT", "KEY WARN", "P RNG WARN" or "ACC WARN" on screen.
Does warning buzzer sound?
Yes: Warning buzzer into combination meter is OK.
No: GO TO 2.
- CHECK OTHER WARNING CHIME OPERATION
Confirm other warning chime function. Refer to "LIGHT WARNING CHIME ".
Does other warning chime operate?
Yes: Warning buzzer into combination meter is OK
No: Check warning chime. Refer to "TROUBLE DIAGNOSIS ".