System Description: Initialization
Perform the initialization when the following operations are performed or when the auto up operation is not performed. Refer to INSPECTION AFTER REMOVAL (Front door), INSPECTION AFTER INSTALLATION (Rear door).
- When the power supply to the power window main switch, power window sub-switch or each power window motor is cut off by the removal of battery terminal or the battery fuse is blown.
- Disconnection and connection of power window main switch or each power window sub-switch harness connector.
- Removal and installation of regulator assembly.
- Removal and installation of motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of glass.
- Removal and installation of door glass run.CAUTION: The following operations are not performed under the condition that the initialization is not performed yet.
- Auto up operation
- Anti-pinch function
- Key cylinder switch close operation