Diagnostic Procedure
- CHECK HARNESS CONTINUITY 1
- Turn ignition switch OFF.
- Disconnect Intelligent Key unit and power distribution unit connector.
- Check continuity between Intelligent Key unit connector and power distribution unit connector.TERMINAL CONTINUITY CHART
A B Continuity Intelligent Key unit connector Terminal Power distribution unit connector Terminal M32 3 M30 11 Yes - Check continuity between Intelligent Key unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Intelligent Key unit connector Terminal M32 3 No
OK or NG
OK: GO TO 2.
NG: Repair or replace harness.
- CHECK HARNESS CONTINUITY 2
- Disconnect IPDM E/R connector.
- Check continuity between power distribution unit connector and IPDM E/R connector.TERMINAL CONTINUITY CHART
A B Continuity Power distribution unit connector Terminal IPDM E/R connector Terminal M31 13 E4 4 Yes - Check continuity between power distribution unit connector and ground.TERMINAL CONTINUITY CHART
A Ground Continuity Power distribution unit connector Terminal M31 13 No
OK or NG
OK: Replace IPDM E/R.
NG: Repair or replace harness.