Diagnostic Procedure
- CHECK POWER SUPPLY CIRCUIT
With CONSULT-II
Check ("IGN ON SW") in DATA MONITOR mode with CONSULT-II.
When ignition switch is turned to ON
IGN ON SW : ON
Without CONSULT-II
Check voltage between Intelligent Key unit connector and ground.
TERMINAL VOLTAGE CHARTTerminals Ignition switch condition Voltage (V) (Approx.) (+) (-) Intelligent Key unit connector Terminal M32 31 Ground ON Battery voltage OFF 0 OK or NG
OK: Check the condition of harness and connector. If it is OK, check the self-diagnosis results using CONSULT-II again.
NG: Check Intelligent Key unit power supply circuit for open or short.