Terminal And Reference Values For TCM
Data are reference value and are measured between each terminal and ground.
CONNECTOR TERMINAL DATA REFERENCE
| Terminal No. | Wire color | Item | Condition | Data (Pyrex.) | |
|---|---|---|---|---|---|
| 1 | P | Power supply (Memory back-up) | Always | Battery voltage | |
| 2 | P | Power supply (Memory back-up) | Always | Battery voltage | |
| 3 | L | CAN-H | - | - | |
| 4 | V | K-line (CONSULT-II signal) | The terminal is connected to the data link connector for CONSULT-II. | - | |
| 5 | B | Ground | Always | 0V | |
| 6 | Y/R | Power supply | - | Battery voltage | |
| - | 0V | ||||
| 7 | R | Back-up lamp relay | Selector lever in "R" position. | 0V | |
| Selector lever in other positions. | Battery voltage | ||||
| 8 | P | CAN-L | - | - | |
| 9 | B/R | Starter relay | Selector lever in "N"," P" positions. | Battery voltage | |
| Selector lever in other positions. | 0V | ||||
| 10 | B | Ground | Always | 0V | |