Transfer Control Unit Terminals And Reference Value
Data are reference value and are measured between each terminal and ground.
TRANSFER CONTROL UNIT TERMINALS AND REFERENCE VALUE CHART
| Terminal | Wire color | Item | Condition | Data (Approx.) | |
|---|---|---|---|---|---|
| 35 | BR/W | Line pressure switch |
|
|
0V |
|
|
Battery voltage | |||
CAUTION:
When using a circuit tester to measure voltage for inspection, be sure not to extend forcibly any connector terminals.