Diagnosis Procedure
- CHECK INTAKE SYSTEM
Check the following for connection.
- Air duct
- Vacuum hoses
- Intake air passage between air duct and intake manifold
Is the inspection result normal?
YES: GO TO 2.
NO: Reconnect the parts.
- CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT
- Disconnect mass air flow sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between mass air flow sensor harness connector and ground.
DTC Mass air flow sensor Ground Voltage Bank Connector Terminal P0101 1 F31 5 Ground Battery voltage P010B 2 F42 5 Is the inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors E106, M6
- Harness connectors M116, F103
- Harness for open or short between mass air flow sensor and ECM
- Harness for open or short between mass air flow sensor and IPDM E/R
: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK MASS AIR FLOW SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between MAF sensor harness connector and ECM harness connector.
DTC Mass air flow sensor ECM Continuity Bank Connector Terminal Connector Terminal P0101 1 F31 4 F113 68 Existed P010B 2 F42 4 94 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 5.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK MASS AIR FLOW SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between mass air flow sensor harness connector and ECM harness connector.
DTC Mass air flow sensor ECM Continuity Bank Connector Terminal Connector Terminal P0101 1 F31 3 F113 77 Existed P010B 2 F42 3 79 - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between mass air flow sensor harness connector and ECM harness connector.
- CHECK INTAKE AIR TEMPERATURE SENSOR
Check intake air temperature sensor. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 9.
NO: Replace mass air flow sensor (with intake air temperature sensor). Refer to "REMOVAL AND INSTALLATION ".
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES-1 (DTC P0101 is detected): GO TO 8.
YES-2 (DTC P010B is detected): GO TO 9.
NO: Replace EVAP control system pressure sensor. Refer to "VQ37VHR: EXPLODED VIEW ".
- CHECK MASS AIR FLOW SENSOR (BANK 1)
Check mass air flow sensor (bank 1). Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace mass air flow sensor (bank 1). Refer to "REMOVAL AND INSTALLATION ".
- CHECK MASS AIR FLOW SENSOR (BANK 2)
Check mass air flow sensor (bank 2). Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Replace mass air flow sensor (bank 2). Refer to "REMOVAL AND INSTALLATION ".