Work Procedure When Replacing Control Unit
- PERFORM ZERO POINT RESET
Perform zero point reset. Refer to "ZERO POINT RESET: SPECIAL REPAIR REQUIREMENT ".
Is zero point reset performed normally?
YES: INSPECTION END
NO: Check condition as per the following, and perform zero point reset again.
- Passenger seat is occupied by an object.
- Excessive vibration is applied while performing zero point reset.
- Occupant detection system is malfunctioning.NOTE: If "Incomplete" is displayed on "zero point reset current status", zero point reset is not completed normally. Check the condition as per the following and perform zero point reset again.
- Passenger seat is occupied by an object.
- Excessive vibration is applied while performing zero point reset.
- Occupant detection system is malfunctioning.