Driving Pattern B
Driving pattern B means a trip satisfying the following conditions.
- Engine speed reaches 400 RPM or more.
- Engine coolant temperature reaches 70°C (158°F) or more.
- Vehicle speed of 70 - 120 km/h (44 - 75 MPH) is maintained for 60 seconds or more under the control of closed loop.
- Vehicle speed of 30 - 60 km/h (19 - 37 MPH) is maintained for 10 seconds or more under the control of closed loop.
- After experiencing the closed loop control with the hybrid system started (READY or engine started), vehicle speed of 4 km/h (2 MPH) or less and the status without stepping on the accelerator pedal are maintained for 12 seconds or more.
- The state of driving at 10 km/h (7 MPH) or more reaches 10 minutes or more in total.
- The status with the hybrid system started (READY or engine started) is maintained for 22 minutes or more.
NOTE:
- Drive the vehicle at a constant velocity.
- When the same malfunction is detected regardless of driving conditions, reset the counter of driving pattern B.