Component Function Check
- CHECK FUNCTION
- Select "TILT SW-UP", "TILT SW-DOWN" in "Data monitor" mode with CONSULT.
- Check tilt switch signal under the following conditions.
Monitor item Condition Status TILT SW-UP Tilt switch (up) Operate ON Release OFF TILT SW-DOWN Tilt switch (down) Operate ON Release OFF Is the indication normal?
YES: INSPECTION END
NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".