Diagnosis Procedure
- CHECK FRP SENSOR POWER SUPPLY-I
- Turn ignition switch OFF.
- Disconnect FRP sensor connector.
- Turn ignition switch ON.
- Check the voltage between FRP sensor harness connector terminals.
FRP sensor Voltage (Approx.) Connector + - terminal F6 1 3 5 V Inspection result normal?
YES: GO TO 6.
NO: GO TO 2.
- CHECK FRP SENSOR POWER SUPPLY-II
Check the voltage between FRP sensor harness connector and the ground.
+ - Voltage (Approx.) FRP sensor Connector Terminal F6 1 Ground 5 V Is inspection result normal?
YES: GO TO 4.
NO: GO TO 3.
- CHECK SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness connector for short to power and short to ground, between the following terminals.
ECM Sensor Connector Terminal Name Connector Terminal F110 27 Power steering pressure sensor F35 3 Low fuel pressure sensor F39 3 28 FRP sensor F6 1 Engine oil pressure sensor F32 3 Is inspection result normal?
YES: Perform the trouble diagnosis for power supply circuit. Refer to "DIAGNOSIS PROCEDURE ".
NO: Repair or replace error-detected parts.
- CHECK FRP SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
+ - Continuity FRP sensor ECM Connector Terminal Connector Terminal F6 3 F110 40 Existed Is inspection result normal?
YES: GO TO 5.
NO: Repair or replace error-detected parts.
- CHECK ECM GROUND CIRCUIT
Check the continuity between ECM harness connector and the ground.
ECM Ground Continuity Connector Terminal F110 10 Ground Existed M160 114 115 174 175 Is inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Repair or replace error-detected parts.
- CHECK FRP SENSOR SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
+ - Continuity FRP sensor ECM Connector Terminal Connector Terminal F6 2 F110 31 Existed - Also check harness for short to ground and to power.
Is inspection result normal?
YES: GO TO 7.
NO: Repair or replace error-detected parts.
- CHECK FRP SENSOR
Refer to "COMPONENT INSPECTION (FUEL RAIL PRESSURE SENSOR) ".
Is inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Repair or replace error-detected parts.