Special Repair Requirement

CAUTION: After removing/replacing the yaw rate/side/decal G sensor or replacing the ABS actuator and electric unit (control unit), the decel G sensor of the ABS actuator and electric unit (control unit) must be calibrated first. Refer to "DESCRIPTION ".
  1. PREPARATION BEFORE CALIBRATION PROCEDURE 
    1. Park the vehicle on a flat road.
    2. Adjust pressure in all tires to the specified value. Refer to "TIRE AIR PRESSURE ".

      GO TO 2.

  2. PERFORM CALIBRATION 

    With CONSULT 

    1. Turn ignition switch ON.
      CAUTION: Never start the engine.
    2. Select "G SENSOR CALIBRATION" in "Work Support" in "TRANSMISSION".
    3. Touch "START".
      CAUTION: Never give any motion to the vehicle during the calibration.

    Is "completed" displayed? 

    YES: GO TO 3.

    NO: Perform the calibration again.

  3. CHECK DTC 

    With CONSULT 

    1. Turn ignition switch OFF and wait 10 seconds or more.
    2. Turn ignition switch ON.
    3. Select "Self Diagnostic Results" in "ABS".

    Is "C1145" or "C1146" detected? 

    YES: Refer to "DTC INDEX ".

    NO: Calibration end.