Diagnosis Procedure
- CHECK CONTINUITY RGB (B: BLUE) SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and AV control unit connector.
- Check continuity between display unit harness connector and AV control unit harness connector.
Display unit AV control unit Continuity Connector Terminal Connector Terminal M71 18 M202 45 Existed - Check continuity between display unit harness connector and ground.
Display unit Ground Continuity Connector Terminal M71 18 Not existed
Is inspection result normal?
YES
GO TO STEP 2 .
NO
Repair harness or connector.
- CHECK RGB (B: BLUE) SIGNAL
- Connect display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.
(+) (-) Condition Reference value Display unit Connector Terminal M71 18 Ground Start confirmation/adjustment mode, and then display color bar by selecting "Color Spectrum Bar" on DISPLAY DIAGNOSIS screen.
Is inspection result normal?
YES
Replace display unit. Refer to EXPLODED VIEW .
NO
Replace AV control unit. Refer to EXPLODED VIEW .