Diagnosis Procedure
- CHECK CONTINUITY DISK EJECT SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect multifunction switch connector and AV control unit connector.
- Check continuity between multifunction switch harness connector and AV control unit harness connector.
Multifunction switch AV control unit Continuity Connector Terminal Connector Terminal M72 14 M204 96 Existed - Check continuity between multifunction switch harness connector and ground.
Multifunction switch Ground Continuity Connector Terminal M72 14 Not existed
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair harness or connector.
- CHECK AV CONTROL UNIT VOLTAGE
- Connect multifunction switch connector and AV control unit connector.
- Turn ignition switch ON.
- Check voltage between AV control unit harness connector and ground.
(+) (-) Condition Voltage
(Approx.)AV control unit Connector Terminal M204 96 Ground Pressing the eject switch 0 V Except for above 3.3 V
Is the inspection result normal?
YES
Replace preset switch. Refer to EXPLODED VIEW .
NO
Replace AV control unit. Refer to EXPLODED VIEW .