Detail Flow - Tilt & Telescopic
| Order | Input | Output | Control unit condition |
|---|---|---|---|
| 1 | Tilt & telescopic switch | - | The tilt & telescopic switch signals are inputted to the automatic drive positioner control unit when the tilt & telescopic switch are operated. |
| 2 | - | Motors (Tilt, telescopic) |
The automatic drive positioner control unit actuates each motor according to the operation of the tilt & telescopic switch. |
| 3 | Sensors (Tilt, telescopic) |
- | The automatic drive positioner control unit recognizes any operation limit of each actuator via each sensor and will not operate the actuator anymore at that time.* |
*: Tilt does not operates upward when tilt sensor value is less than 1.1 V, tilt does not operate downward when the sensor value is more than 3.9 V. Telescopic does not operates backward when telescopic sensor value is less than 0.5 V, telescopic does not operate forward when the sensor value is more than 4.5 V.