Component Function Check
- CHECK OPERATION OF METER BUZZER
- Connect the CONSULT.
- Perform "LIGHT WARN ALM" in "ACTIVE TEST" of "BCM (BUZZER)".
Does meter buzzer beep?
YES
INSPECTION END
NO
GO TO STEP 2.
- CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL
Select the "Data Monitor" of "METER/M&A" and check the "BUZZER" monitor value.
"BUZZER" Under the condition of buzzer input : On Except above : Off Is the inspection result normal?
YES
Replace combination meter.
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION .