Diagnostic Test
- CHECK HOOD SWITCH
- Turn ignition switch OFF.
- Disconnect hood switch connector.
- Check continuity between hood switch terminals.
Hood switch Condition Continuity Terminal 1 2 Hood Close the hood Not existed Open the hood Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace hood lock (RH). Refer to REMOVAL AND INSTALLATION .