Diagnosis Procedure
- CHECK CONTINUITY RGB SYNCHRONIZING SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect display unit connector and AV control unit connector.
- Check continuity between display unit harness connector and AV control unit harness connector.
Display unit AV control unit Continuity Connector Terminal Connector Terminal M194 19 M215 42 Existed - Check continuity between display unit harness connector and ground.
Display unit Ground Continuity Connector Terminal M194 19 Not existed
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair harness or connector.
- CHECK RGB SYNCHRONIZING SIGNAL
- Connect display unit connector and AV control unit connector.
- Turn ignition switch ON.
- Check signal between display unit harness connector and ground.
(+) (-) Reference value Display unit Connector Terminal M194 19 Ground
Is the inspection result normal?
YES
Replace display unit. Refer to EXPLODED VIEW .
NO
Replace AV control unit. Refer to EXPLODED VIEW .