Calibrating Camera Image
- Perform the calibration of camera image caused by the incorrect mounting position of each camera, etc. Always perform calibration after performing the following work.
- When each camera or each camera mount (door mirror, front grille, etc.) is removed
- When replacing around view monitor control unit
- When performing the calibration initialization, it can be set to the NISSAN factory shipment condition.
Refer to DESCRIPTION for the calibration procedure.
| Adjustment Range | |
| Rotating Direction | 31 patterns (16 on the center) |
| Upper/Lower Direction | -99 - 99 |
| Left/Right Direction | -99 - 99 |
CALIBRATING CAMERA IMAGE ITEM
| Items | Description |
|---|---|
| Rear Camera | Performs the calibration of rear camera. |
| Pass-Side Camera | Performs the calibration of side camera RH. |
| Front Camera | Performs the calibration of front camera. |
| Dr-Side Camera | Performs the calibration of side camera LH. |
| Initialize Camera Image Calibration* | The calibration can be initialized to the factory shipment setting. |
CAUTION:
* : Never perform other operations for approximately 10 seconds after performing "Initialize Camera Image Calibration".