Compressor Protection Control At Pressure Malfunction
When High - Pressure Side Value That Is Detected By Refrigerant Pressure Sensor Is As Per The Following State, Ecm Requests Ipdm E/R To Turn A/C Relay Off And Stops The Compressor.
- 3.12 Mpa (31.82 Kg/Cm2 , 452.4 Psi) Or More (When The Engine Speed Is Less Than 1, 500 Rpm)
- 2.74 Mpa (27.95 Kg/Cm2 , 397.3 Psi) Or More (When The Engine Speed Is 1, 500 Rpm Or More)
- 0.14 Mpa (1.43 Kg/Cm2 , 20.3 Psi) Or Less