LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2015 >> QX80 Base, AWD >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostic Trouble Codes (DTCS) P0181-P1550) >> DTC/Circuit Diagnosis >> DTC P0452: EVAP Control System Pressure Sensor >> Diagnosis Procedure >> Diagnostic Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Test

  1. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR

    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check that water is not inside connectors.

    Is the inspection result normal?

    YES 

    GO TO STEP 2  .

    NO 

    Repair or replace harness connector.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I

    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.
      EVAP control system pressure sensor Ground Voltage (V)
      Connector Terminal
      C17 3 Ground Approx. 5

    Is the inspection result normal?

    YES 

    GO TO STEP 9  .

    NO 

    GO TO STEP 3  .

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II

    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      C17 3 E80 133 Existed

    Is the inspection result normal?

    YES 

    GO TO STEP 5  .

    NO 

    GO TO STEP 4  .

  4. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness for open between ECM and EVAP control system pressure sensor
    • Loose or poor connection for each connector and harness

    Repair open circuit.

  5. CHECK SENSOR POWER SUPPLY CIRCUIT

    Check harness for short to power and short to ground, between the following terminals.

    ECM Sensor
    Connector Terminal Name Connector Terminal
    F110 76 Crankshaft position sensor F74 1
    77 Camshaft position sensor (bank 1) F84 1
    E80 133 EVAP control system pressure sensor C17 3
    Battery current sensor E63 2
    Refrigerant pressure sensor E77 1
    131 APP sensor 2 (Without ICC) E110 1
    APP sensor 2 (with ICC) E213 10

    Is the inspection result normal?

    YES 

    GO TO STEP 6  .

    NO 

    Repair short to ground or short to power in harness or connectors.

  6. CHECK COMPONENTS

    Check the following.

    Is the inspection result normal?

    YES 

    GO TO STEP 7  .

    NO 

    Replace malfunctioning component.

  7. CHECK APP SENSOR

    Refer to COMPONENT INSPECTION (ACCELERATOR PEDAL POSITION SENSOR) .

    Is the inspection result normal?

    YES 

    GO TO STEP 14  .

    NO 

    GO TO STEP 8  .

  8. REPLACE ACCELERATOR PEDAL ASSEMBLY

    Replace accelerator pedal assembly.

    Refer to REMOVAL AND INSTALLATION (Without distance control assist system)

    Refer to REMOVAL AND INSTALLATION (With distance control assist system).

    INSPECTION END

  9. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT

    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      C17 1 E80 150 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES 

    GO TO STEP 11  .

    NO 

    GO TO STEP 10  .

  10. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness for open or short between EVAP control system pressure sensor and ECM
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connectors.

  11. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

    1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
      EVAP control system pressure sensor ECM Continuity
      Connector Terminal Connector Terminal
      C17 2 E80 143 Existed
    2. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES 

    GO TO STEP 13  .

    NO 

    GO TO STEP 12  .

  12. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness for open or short between EVAP control system pressure sensor and ECM
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connectors.

  13. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to COMPONENT INSPECTION (EVAP CONTROL SYSTEM PRESSURE SENSOR) .

    Is the inspection result normal?

    YES 

    GO TO STEP 14  .

    NO 

    Replace EVAP control system pressure sensor. Refer to EXPLODED VIEW .

  14. CHECK INTERMITTENT INCIDENT

    Refer to INTERMITTENT INCIDENT .

    INSPECTION END