Diagnostic Test
- CHECK STOP LAMP SWITCH-I
- Turn ignition switch OFF.
- Disconnect stop lamp switch harness connector.
- Check the continuity between stop lamp switch terminals under the following conditions.
Terminals Condition Continuity 1 and 2 Brake pedal Fully released Not existed Slightly depressed Existed
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO STEP 2 .
- CHECK STOP LAMP SWITCH-II
- Adjust stop lamp switch installation. Refer to INSPECTION AND ADJUSTMENT .
- Check the continuity between stop lamp switch terminals under the following conditions.
Terminals Condition Continuity 1 and 2 Brake pedal Fully released Not existed Slightly depressed Existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace stop lamp switch. Refer to EXPLODED VIEW WITH TORQUE SPECIFICATIONS .