Gasoline engine models
- CHECK FUSE
- Turn ignition switch OFF.
- Check that the following fuse in the fuse block (J/B) is not blown (open).
Signal name
Fuse No.
Battery power supply
6 (10 A)
Ignition power supply
11 (5 A)
Is the fuse blown (open)?
YES
Replace the blown (open) fuse after repairing the cause of blowing.
NO
GO TO 2.
- CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector and ground.
(+)
(-)
Condition
Voltage
Combination meter
Connector
Terminal
M58
45
Ground
Ignition switch
ON
Battery voltage
46
OFF, ACC or ON
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness.
- CHECK SECURITY INDICATOR LAMP SIGNAL
- Connect combination meter connector.
- Disconnect BCM connector.
- Check voltage between BCM harness connector and ground.
(+)
(-)
Voltage
BCM
Connector
Terminal
M13
18
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 5.
- REPLACE BCM
Replace BCM. Refer to BCM : Removal & Installation .
INSPECTION END
- CHECK SECURITY INDICATOR LAMP CIRCUIT
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and BCM harness connector.
Combination meter
BCM
Continuity
Connector
Terminal
Connector
Terminal
M57
7
M13
18
Existed
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M57
7
Not existed
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER : Removal & Installation .
NO
Repair or replace harness.