Fail-Safe Function
| DTC | Vehicle Condition | Vehicle Behavior For 1st Fail-Safe | Vehicle Behavior For 2nd Fail-Safe | Vehicle Behavior For Final Fail-Safe | |
|---|---|---|---|---|---|
| P062F | - | - | - | - | |
| P0705 | - |
|
- |
|
|
| P0710 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0717 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0720 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0720 and P1721 |
- | Locks in 5GR | - | Locks in 5GR | |
| P0725 | - | - | - | - | |
| P0729 P0731 P0732 P0733 P0734 P0735 P1734 |
Small gear ratio difference | Engine torque limit: Max 150 Nm | - | Engine torque limit: Max 150 Nm | |
| Great gear ratio difference | Neutral malfunction between the gears of 1 - 2 - 3 and 7 |
|
- |
|
|
| Other than the above |
|
|
|
||
| P0730 | - |
|
|
|
|
| P0740 | - |
|
- |
|
|
| P0744 | - |
|
- |
|
|
| P0745 | - | - | - | - | |
| P0750 P0775 P0795 P2713 P2722 P2731 P2807 |
- |
|
- |
|
|
| P0780 | - |
|
- |
|
|
| P0877 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| P0878 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| P161A | - | No permission for engine start. | - | No permission for engine start. | |
| P1705 | - |
|
|
|
|
| P1721 | - | - | - | - | |
| P1730 | - |
|
|
|
|
| P1815 | Gate switch malfunction | Only the gate switch is prohibited | - | Only the gate switch is prohibited | |
| Paddle switch malfunction | Only the paddle switch is prohibited | - | Only the paddle switch is prohibited | ||
| Malfunction of both switches | Manual mode is prohibited | - | Manual mode is prohibited | ||
| P188E | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| P1890 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| P2796 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| P2798 | - | Locks in 5GR | - | Locks in 5GR | |
| U0100 U0300 U1000 |
Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| U0101 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| U1115 | - | Stop/start system is prohibited | - | Stop/start system is prohibited | |
| DTC | Vehicle Condition | Vehicle Behavior For 1st Fail-Safe | Vehicle Behavior For 2nd Fail-Safe | Vehicle Behavior For Final Fail-Safe | |
|---|---|---|---|---|---|
| P0615 | - | Starter is disabled | - | Starter is disabled | |
| P0705 | - |
|
- |
|
|
| P0710 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0717 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0720 | Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0725 | - | - | - | - | |
| P0729 P0731 P0732 P0733 P0734 P0735 P1734 |
Small gear ratio difference | Engine torque limit: Max 150 Nm | - | Engine torque limit: Max 150 Nm | |
| Great gear ratio difference | Neutral malfunction between the gears of 1 - 2 - 3 and 7 |
|
- |
|
|
| Other than the above |
|
|
|
||
| P0730 | - |
|
|
|
|
| P0740 | - |
|
- |
|
|
| P0744 | - |
|
- |
|
|
| P0745 | - | - | - | - | |
| P0750 P0775 P0795 P2713 P2722 P2731 P2807 |
- |
|
- |
|
|
| P0780 | - |
|
- |
|
|
| P1705 | - |
|
|
|
|
| P1721 | - | - | - | - | |
| P1730 | - |
|
|
|
|
| P1815 | Gate switch malfunction | Only the gate switch is prohibited | - | Only the gate switch is prohibited | |
| Paddle switch malfunction | Only the paddle switch is prohibited | - | Only the paddle switch is prohibited | ||
| Malfunction of both switches | Manual mode is prohibited | - | Manual mode is prohibited | ||
| U0100 U0300 U1000 |
Between the gears of 1 - 2 - 3 |
|
- |
|
|
| Between the gears of 4 - 5 - 6 - 7 |
|
- | |||
| P0720 and P1721 |
- | Locks in 5GR | - | Locks in 5GR | |