Work Procedure (Group A)
WARNING: This page is about a different variant/trim than selected.
| *1: | When the same malfunction is detected in two consecutive trips, MIL will illuminate. |
- CHECK DTC
Check DTC.
Is any DTC detected?
YES
Repair malfunction(s) and erase DTC.
NO
GO TO STEP 2 .
- CHECK PERMANENT DTC
With CONSULT
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- On CONSULT screen, select "SRT & P-DTC">>"Permanent DTC Status".
With GST
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Select Service $0A with GST.
Is any permanent DTC detected?
YES
GO TO STEP 3 .
NO
END
- PERFORM DTC CONFIRMATION PROCEDURE
Perform "DTC CONFIRMATION PROCEDURE" for DTCs which are the same as permanent DTCs stored in ECM. Refer to DTC INDEX (For turbo high pressure model) or DTC INDEX (For turbo low pressure model).
GO TO STEP 4 .
- CHECK PERMANENT DTC
With CONSULT
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- On CONSULT screen, select "SRT & P-DTC">>"Permanent DTC Status".
With GST
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Turn Ignition Switch ON.
- Select Service $0A with GST.
Is any permanent DTC detected?
YES
GO TO STEP 1 .
NO
END