Diagnosis Procedure
- CHECK CAMERA SWITCH INPUT SIGNAL OF DISPLAY CONTROL UNIT
- Turn Ignition Switch ON.
- Check the voltage between display Control Unit harness connector and ground.
Terminals Condition Voltage
(Approx.)(+) (-) Display Control Unit Connector Terminal M100 26 Ground Camera switch ON 0 - 2.5 V OFF 3.0 V
Is the inspection result normal?
YES
Replace display Control Unit. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 2 .
- CHECK CAMERA SWITCH INPUT SIGNAL OF INTEGRAL SWITCH
Check the voltage between integral switch harness connector and ground.
Terminals Condition Voltage
(Approx.)(+) (-) Integral switch Connector Terminal M1 19 Ground Camera switch ON 0 - 2.5 V OFF 3.0 V Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 5 .
- CHECK CAMERA SWITCH INPUT SIGNAL CIRCUIT OF DISPLAY CONTROL UNIT FOR OPEN
- Turn Ignition Switch OFF.
- Disconnect display Control Unit harness connector and integral switch harness connector.
- Check the continuity between display Control Unit harness connector and integral switch harness connector.
Display Control Unit Integral switch Continuity Connector Terminal Connector Terminal M100 26 M1 19 Existed
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace malfunctioning parts.
- CHECK CAMERA SWITCH INPUT SIGNAL CIRCUIT OF DISPLAY CONTROL UNIT FOR SHORT
Check the continuity between display Control Unit harness connector and ground.
Display Control Unit Ground Continuity Connector Terminal M100 26 Not existed Is the inspection result normal?
YES
Replace integral switch. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace malfunctioning parts.
- CHECK CAMERA SWITCH INPUT SIGNAL CIRCUIT OF INTEGRAL SWITCH FOR OPEN
- Turn Ignition Switch OFF.
- Disconnect integral switch harness connector and multifunction switch harness connector.
- Check the continuity between integral switch harness connector and multifunction switch harness connector.
Integral switch Multifunction switch Continuity Connector Terminal Connector Terminal M3 39 M55 10 Existed
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace malfunctioning parts.
- CHECK CAMERA SWITCH INPUT SIGNAL CIRCUIT OF INTEGRAL SWITCH FOR SHORT
Check the continuity between integral switch harness connector and ground.
Integral switch Ground Continuity Connector Terminal M3 39 Not existed Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace malfunctioning parts.
- CHECK MULTIFUNCTION SWITCH
Check multifunction switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace multifunction switch. Refer to REMOVAL AND INSTALLATION .