Consult Data Monitor Reference Values
NOTE:
The following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.
| Monitor Item | Condition | Value/Status | |
|---|---|---|---|
| COMP REQ SIG | Ignition Switch ON | A/C Switch: ON (A/C Switch indicator lamp: ON) | On |
| A/C Switch: OFF (A/C Switch indicator lamp: OFF) | Off | ||
| FAN REQ SIG | Engine: Run at idle after warming up | Blower Motor: ON | On |
| Blower Motor: OFF | Off | ||
| BLOWER MOT VOLT |
NOTE:
This item is indicated, but not monitored. |
0 V | |
| GAS SEN LEVEL * | Ignition Switch ON | Values depending on contamination of ambient air | |
| AMB TEMP SEN | Ignition Switch ON | Equivalent to ambient temperature | |
| IN - VEH TEMP | Ignition Switch ON | Equivalent to in-vehicle temperature | |
| INT TEMP SEN | Ignition Switch ON | Equivalent to evaporator fin temperature | |
| SUNLOAD SEN | Ignition Switch ON | Equivalent to sunload amount | |
| AMB SEN CAL | Ignition Switch ON | Equivalent to ambient temperature | |
| IN - VEH CAL | Ignition Switch ON | Equivalent to in-vehicle temperature | |
| INT TEMP CAL | Ignition Switch ON | Equivalent to evaporator fin temperature | |
| SUNL SEN CAL | Ignition Switch ON | Equivalent to sunload amount | |
| COMP ECV DUTY | Engine: Run at idle after warming up | A/C Switch: ON (A/C Switch indicator lamp: ON) | 1 - 100% |
| A/C Switch: OFF (A/C Switch indicator lamp: OFF) | 0% | ||
| FAN DUTY | Engine: Run at idle after warming up | Blower Motor: ON | 25 - 79 |
| Blower Motor: OFF | 0 | ||
| XM | Ignition Switch ON | Value according to target air flow temperature (driver side) | |
| ENG COOL TEMP | Ignition Switch ON | Equivalent to engine coolant temperature | |
| VEHICLE SPEED | Turn drive wheels and compare CONSULT value with the speedometer indication. | Equivalent to speedometer reading | |
* : With ACCS