High In-Vehicle Temperature Starting Control
When evaporator temperature is high [Intake Sensor value is 35°C (95°F) or more], to prevent a hot discharged air flow, A/C Auto Amp. suspends Blower Motor activation for approximately 3 seconds so that evaporator is cooled by refrigerant.