Monitor Item Unit Contents
STARTERSW On/Off The Ignition Switch position "OFF (other than cranking) / ON (cranking)" judged from the Ignition Switch signal.
SETSW On/Off ON/OFF status judged from the setting Switch signal.
MEMORYSW 1 On/Off ON/OFF status judged from the Seat Memory Switch 1 signal.
MEMORYSW 2 On/Off ON/OFF status judged from the Seat Memory Switch 2 signal.
DETENTSW On/Off The selector lever status "OFF (P position) / ON (other than P position or press the selector button with selector lever in P position)" judged from the detention Switch signal.
STEERING STATUS LOCK/UNLOCK Power supply position "LOCK/UNLOCK (other than lock)" judged by BCM.
SLIDESW-FR On/Off ON/OFF status judged from the Sliding Switch (forward) signal.
SLIDESW-RR On/Off ON/OFF status judged from the Sliding Switch (backward) signal.
RECLNSW-FR On/Off ON/OFF status judged from the Reclining Switch (forward) signal.
RECLNSW-RR On/Off ON/OFF status judged from the Reclining Switch (backward) signal.
LIFTFRSW-UP On/Off ON/OFF status judged from the lifting Switch front (up) signal.
LIFTFRSW-DN On/Off ON/OFF status judged from the lifting Switch front (down) signal.
LIFTRRSW-UP On/Off ON/OFF status judged from the lifting Switch rear (up) signal.
LIFTRRSW-DN On/Off ON/OFF status judged from the lifting Switch rear (down) signal.
TILT SW-UP On/Off ON/OFF status judged from the tilt Switch (up) signal.
TILT SW-DOWN On/Off ON/OFF status judged from the tilt Switch (down) signal.
TELESCO SW-FR On/Off ON/OFF status judged from the telescoping Switch (forward) signal.
TELESCO SW-RR On/Off ON/OFF status judged from the telescoping Switch (backward) signal.
MIRCONSW-UP On/Off ON/OFF status judged from the mirror Switch (up) signal.
MIRCONSW-DN On/Off ON/OFF status judged from the mirror Switch (down) signal.
MIRCONSW-RH On/Off ON/OFF status judged from the Door Mirror Remote Control Switch (passenger side) signal.
MIRCONSW-LH On/Off ON/OFF status judged from the Door Mirror Remote Control Switch (driver side) signal.
MIRCHNGSW-R On/Off ON/OFF status judged from the Door Mirror Remote Control Switch (Switching to right) signal.
MIRCHNGSW-L On/Off ON/OFF status judged from the Door Mirror Remote Control Switch (Switching to left) signal.
TILT PULSE - Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.
TELESCO PULSE - Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.
MIR/SENRHU-D V Voltage input from door Mirror Sensor (passenger side) up/down is displayed.
MIR/SENRHR-L V Voltage input from door Mirror Sensor (passenger side) left/right is displayed.
MIR/SENLHU-D V Voltage input from door Mirror Sensor (driver side) up/down is displayed.
MIR/SENLHR-L V Voltage input from door Mirror Sensor (driver side) left/right is displayed.
SLIDE PULSE - Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.
RECLN PULSE - Value (32768) when battery connections are standard. If it moves backward, the value increases. If it moves forward, the value decreases.
LIFT FR PULSE - Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.
LIFT RR PULSE - Value (32768) when battery connections are standard. If it moves DOWN, the value increases. If it moves UP, the value decreases.
VEHICLE SPEED - Display the vehicle speed signal received from combination meter by numerical value [km/h].
P RANG SW CAN On/Off ON/OFF status judged from the P range Switch signal.
R RANGE (CAN) On/Off ON/OFF status judged from the R range Switch signal.
DOORSW-FL Open/Close OPEN/CLOSE status judged from the door Switch (driver side) signal.
DOORSW-FR Open/Close OPEN/CLOSE status judged from the door Switch (passenger side) signal.
IGN ON SW On/Off ON/OFF status judged from the Ignition Switch signal.
ACC ON SW On/Off ON/OFF status judged from the ACC Switch signal.
KYLS DR UNLK On/Off ON/OFF status judged from the driver side door unlock actuator output Switch signal.
KEYLESS ID ID1/ID2/ID3/ID4 Key ID status judged from the key ID signal.
VHCL SPEED (ABS) RCV/NORCV Received/Not received status judged from vehicle speed signal.
HANDLE LHD/RHD RHD/LHD status judged from handle position signal.
TRANSMISSION AT/MT AT/MT status judged from transmission.
INITIAL STATE DONE/YET Displays the default status of the log-in function.
USER1 REGIST DONE/YET Displays the USER1 registration or non-registration status of the log-in function.
USER2 REGIST DONE/YET Displays the USER2 registration or non-registration status of the log-in function.
USER3 REGIST DONE/YET Displays the USER3 registration or non-registration status of the log-in function.
USER4 REGIST DONE/YET Displays the USER4 registration or non-registration status of the log-in function.
LOGIN USER User1/User2/User3/User4 Displays the current log-in user with the log-in function.
USER1 SW On/Off ON/OFF status judged from user1 change Switch signal.
USER2 SW On/Off ON/OFF status judged from user2 change Switch signal.
USER3 SW On/Off ON/OFF status judged from user3 change Switch signal.
USER4 SW On/Off ON/OFF status judged from user4 change Switch signal.
LOGIN USER CHANGE PRBT/PRMT Display the user change permission or inhibition status of the log-in function.
KEY LINK FUNCTION On/Off Displays the ON/OFF status of the Intelligent Key interlock function.
KEY NUMBER KEY 1/KEY 2/KEY 3/KEY 4
NOTE:

This item is displayed, but cannot be monitored

KEY 1 NO REG/ACT/INACT
NOTE:

This item is displayed, but cannot be monitored

KEY 2 NO REG/ACT/INACT
NOTE:

This item is displayed, but cannot be monitored

KEY 3 NO REG/ACT/INACT
NOTE:

This item is displayed, but cannot be monitored

KEY 4 NO REG/ACT/INACT
NOTE:

This item is displayed, but cannot be monitored

Log-in user setting 1 Off/User1/User2/User3/User4 The user number that is used for transmitting the settings of the log-in function is displayed.
Log-in user setting 2 Off/User1/User2/User3/User4 The user number that is used for receiving the settings of the log-in function is displayed.
Log-in user setting copy status On/Off The copy status of the Log-in function is displayed with "On/Off".
Forward SW On/Off ON (folded down)/OFF (other than folded down) status judged from the folded up/folded down condition signal.
Walk in SW On/Off ON (pressed)/OFF (other than pressed) status judged from the Power Walk-In Switch operation signal.
Forward limit SW On/Off ON (front edge)/OFF (other than front edge) status judged from the front end position signal.
Seat belt buckle SW On/Off ON (fastened)/OFF (other than fastened) status judged from the seat belt fastening/releasing condition signal.