DTC Detection Logic
| DTC No. | CONSULT screen terms | DTC detecting condition | ||
|---|---|---|---|---|
| (Trouble diagnosis content) | Malfunction type | |||
| P0036 | 13 | HO2S HEATER B1 SEN2 (HO2S heater control circuit bank 1 sensor 2) |
CIRCUIT OPEN | The output for the heater of oxygen sensor (cylinder bank 1) has an electrical malfunction or open circuit. There is an open circuit. |
| P0037 | 11 | HO2S HEATER B1 SEN2 (HO2S heater control circuit low bank 1 sensor 2) |
CIRCUIT SHORT TO GROUND | The output for the heater of oxygen sensor (cylinder bank 1) has a short circuit to ground. There is a short circuit to ground. |
| P0038 | 12 | HO2S HEATER B1 SEN2 (HO2S heater control circuit high bank 1 sensor 2) |
CIRCUIT SHORT TO BATTERY | The output for the heater of oxygen sensor (cylinder bank 1) has a short circuit to positive. There is a short circuit to positive. |