Diagnostic Test
- CHECK HEATED OXYGEN SENSOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between heated oxygen sensor harness connector and ground.
+ - Voltage Heated oxygen sensor Connector Terminal F144 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK HEATED OXYGEN SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Check that #214 fuse is not fusing.
- Check the continuity between heated oxygen sensor harness connector and fuse terminal.
+ - Continuity Heated oxygen sensor Connector Terminal F144 1 #214 fuse terminal Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Perform trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK HEATED OXYGEN SENSOR HEATER CONTROL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between heated oxygen sensor harness connector and ECM harness connector.
+ - Continuity Heated oxygen sensor ECM Connector Terminal Connector Terminal F144 2 F149 95 Existed 3 13 4 37 - Also check harness for short to ground, short to power, and short to each circuit.
Is the inspection result normal?
YES
Replace heated oxygen sensor. Refer to EXPLODED VIEW WITH TORQUE SPECIFICATIONS .
NO
Repair or replace error-detected parts.