DTC Detection Logic
| DTC | CONSULT screen terms | MELCO code | DTC detection condition | |||
|---|---|---|---|---|---|---|
| (Trouble diagnosis content) | [Malfunction type] | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 41 | Diagnosis condition | 8.5 V < Battery terminal voltage < 19.2 V |
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.048 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 42 | Diagnosis condition | Battery terminal voltage > 7.5 V |
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.048 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 43 | Diagnosis condition | Battery terminal voltage > 7.5 V |
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.048 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 44 | Diagnosis condition | Initial check |
| Signal (terminal) | - | |||||
| Threshold | Motor terminal voltage is the following condition
|
|||||
| Diagnosis delay time | 0.5 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 45 | Diagnosis condition |
|
| Signal (terminal) | - | |||||
| Threshold | Internal current is the following condition
|
|||||
| Diagnosis delay time | 2 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 46 | Diagnosis condition |
|
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.2 seconds | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 47a | Diagnosis condition |
|
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.1 second | |||||
| C1592 | 09 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] | 47b | Diagnosis condition |
|
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.2 seconds | |||||
| C1592 | 49 | EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[INTERNAL ELECTRONIC ERROR] | 32, 33 | Diagnosis condition | 8.5 V < Battery terminal voltage < 19.2 V |
| Signal (terminal) | - | |||||
| Threshold | Control unit detected the following condition.
|
|||||
| Diagnosis delay time | 0.2 seconds | |||||