Freeze Frame Data (FFD)
The BCM records the following vehicle condition at the time a particular DTC is detected, and displays on CONSULT.
| CONSULT screen item | Indication/Unit | Description | |
|---|---|---|---|
| Vehicle Speed | km/h | Vehicle speed of the moment a particular DTC is detected | |
| ODO/Trip Meter | km | Total mileage (Odometer value) of the moment a particular DTC is detected | |
| Vehicle Condition | SLEEP>LOCK | Power supply position status of the moment a particular DTC is detected * | While turning BCM status from low power consumption mode to normal mode (Power supply position is "LOCK" *) |
| SLEEP>OFF | While turning BCM status from low power consumption mode to normal mode (Power supply position is "OFF".) | ||
| LOCK>ACC | While turning power supply position from "LOCK" * to "ACC" | ||
| ACC>ON | While turning power supply position from "ACC" to "IGN" | ||
| RUN>ACC | While turning power supply position from "RUN" to "ACC" (Except emergency stop operation) | ||
| CRANK>RUN | While turning power supply position from "CRANKING" to "RUN" (From cranking up the engine to run it) | ||
| RUN>URGENT | While turning power supply position from "RUN" to "ACC" (Emergency stop operation) | ||
| ACC>OFF | While turning power supply position from "ACC" to "OFF" | ||
| OFF>LOCK | While turning power supply position from "OFF" to "LOCK" * | ||
| OFF>ACC | While turning power supply position from "OFF" to "ACC" | ||
| ON>CRANK | While turning power supply position from "IGN" to "CRANKING" | ||
| OFF>SLEEP | While turning BCM status from normal mode (Power supply position is "OFF".) to low power consumption mode | ||
| LOCK>SLEEP | While turning BCM status from normal mode (Power supply position is "LOCK" *.) to low power consumption mode | ||
| LOCK | Power supply position is "LOCK" * | ||
| OFF | Power supply position is "OFF" (Ignition switch OFF) | ||
| ACC | Power supply position is "ACC" (Ignition switch ACC) | ||
| ON | Power supply position is "IGN" (Ignition switch ON with engine stopped) | ||
| ENGINE RUN | Power supply position is "RUN" (Ignition switch ON with engine running) | ||
| CRANKING | Power supply position is "CRANKING" (At engine cranking) | ||
| IGN Counter | 0 - 39 | The number of times that ignition switch is turned ON after DTC is detected
|
|
NOTE:
* : Power supply position shifts to "LOCK" from "OFF", when ignition switch is in the OFF position, selector lever is in the P position, and any of the following conditions are met.
- Closing door
- Opening door
- Door is locked using door request switch
- Door is locked using Intelligent Key
The power supply position shifts to "ACC" when the push-button ignition switch (push switch) is pushed at "LOCK".