Diagnostic Test
- CHECK FUSE
- Turn ignition switch OFF.
- Check that the following fuse is not blowing.
Location Fuse No. Capacity IPDM E/R #47 15A
Is the fuse blown (open)?
YES
Replace the fuse after repairing the applicable circuit.
NO
GO TO STEP 2 .
- CHECK GROUND CONNECTION
Check ground connection B19. Refer to Ground Inspection in CIRCUIT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace ground connection.
- CHECK FPCM GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect FPCM harness connectors.
- Check the continuity between FPCM harness connector and ground.
FPCM - Continuity Connector Terminal B50 3 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace error-detected parts.
- CHECK FPCM POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between FPCM harness connector terminals.
FPCM Voltage Connector + - Terminal B50 6 3 Battery voltage
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
GO TO STEP 5 .
- CHECK FPCM POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect FPCM harness connectors.
- Disconnect IPDM E/R harness connectors.
- Check the continuity between IPDM E/R harness connector and FPCM harness connector.
IPDM E/R FPCM Continuity Connector Terminal Connector Terminal E121 15 B50 6 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP RELAY SIGNAL
- Reconnect IPDM E/R harness connectors.
- Turn ignition switch ON.
- Check the voltage between ECM harness connectors.
ECM Voltage + - Connector Terminal Connector Terminal F79 124 E32 204 0 - 1.0 V
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
GO TO STEP 7 .
- CHECK FUEL PUMP RELAY SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connectors.
- Disconnect IPDM E/R harness connectors.
- Check the continuity between IPDM E/R harness connector and ECM harness connector.
IPDM E/R ECM Continuity Connector Terminal Connector Terminal F24 69 F79 124 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO STEP 8 .
NO
Repair or replace error-detected parts.
- CHECK POWER SUPPLY CIRCUIT
Perform trouble diagnosis for power supply circuit.
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace error-detected parts.