Diagnostic Test
- START
Do you have CONSULT?
Do you have CONSULT?
YES
GO TO STEP 2 .
NO
GO TO STEP 3 .
- PERFORM VVEL CONTROL SHAFT Position Sensor ADJUSTMENT
With CONSULT
- Turn Ignition Switch ON.
- Select "VVEL POS SEN ADJ PREP" in "WORK SUPPORT" mode with CONSULT.
- Touch "Start" and wait a few seconds.
- Make sure the "CMPLT" is displayed on CONSULT screen.
- Select "VVEL POSITION SEN- B1" or "VVEL POSITION SEN- B2" in "DATA MONITOR" mode with CONSULT.
- Loosen the VVEL Control Shaft Position Sensor mounting bolt (1).
- Turn the VVEL Control Shaft Position Sensor (2) right and left while monitoring the output voltage of "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" and adjust the output voltage to be within the standard value.
Voltage : 500 +- 48 mV - Tighten the VVEL Control Shaft Position Sensor mounting bolt.
: 7.0 N•m (0.71 kg-m, 62 in-lb) - Reconfirm that the output voltage of "VVEL POSITION SEN- B1" or "VVEL POSITION SEN- B2" is within the standard value.
Voltage : 500 +- 48 mV NOTE:If it varies from the standard value after the bolt is tightened, perform steps 6 to 8 again.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Start engine and warm it up to normal operating temperature.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Perform idle air volume learning. Refer to DESCRIPTION .
INSPECTION END
- PERFORM VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT
Without CONSULT
- Disconnect VVEL Control Shaft Position Sensor Harness Connector.
- Remove VVEL Actuator Motor Relay.
- Turn Ignition Switch ON, wait at least 5 seconds and then turn OFF.
- Reconnect all Harness Connectors disconnected.
- Install VVEL Actuator Motor Relay.
- Turn Ignition Switch ON and wait at least 5 seconds.
- Loosen the VVEL Control Shaft Position Sensor mounting bolt (1).
- Turn the VVEL Control Shaft Position Sensor (2) right and left while monitoring the output voltage between the VVEL Control Module terminals with a tester and adjust the output voltage to be within the standard value.
VVEL Control Module Voltage Bank Connector + - Terminal Terminal 1 E16 3 4 500 +- 48 mV 2 5 6 - Tighten the VVEL Control Shaft Position Sensor mounting bolt.
: 7.0 N•m (0.71 kg-m, 62 in-lb) - Reconfirm that the output voltage of VVEL Control Shaft Position Sensor is within the standard value.
VVEL Control Module Voltage Bank Connector + - Terminal Terminal 1 E16 3 4 500 +- 48 mV 2 5 6 NOTE:If it varies from the standard value after the bolt is tightened, perform steps 7 to 9 again.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Start engine and warm it up to normal operating temperature.
- Turn Ignition Switch OFF and wait at least 10 seconds.
- Perform idle air volume learning. Refer to DESCRIPTION .
INSPECTION END