Av Comm Diagnosis
- Displays the communication status between AV control unit (master unit) and each unit.
- The error counter displays "OK" if any malfunction was not detected in the past and displays "0" if a malfunction is detected. It increases by 1 if the condition is normal at the next ignition switch ON cycle. The upper limit of the counter is 39.
- The error counter is erased if "Reset" is pressed.
Items Status
(Current)Counter
(Past)C Tx(ITM-PrimarySW) OK / ??? OK / 0 - 39 C Rx(PrimarySW-ITM) OK / ??? OK / 0 - 39 C Rx(Amp-ITM) OK / ??? OK / 0 - 39 C Rx(Amp-Audio) OK / ??? OK / 0 - 39 C Rx(AVM-ITM) OK / ??? OK / 0 - 39 C Rx(Disp.3-Video Dist) OK / ??? / - OK / 0 - 39 C Rx(Video Dist-ITM) OK / ??? OK / 0 - 39 C Rx(R.RomoteCont-ITM) OK / ??? OK / 0 - 39 NOTE:"???" indicates UNKWN