Diagnostic Test
- CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-I
- Check the voltage between ECM harness connector and ground under the following conditions.
ECM Ground Condition Voltage Connector Terminal F92 111 Ground Ignition switch: OFF Approx. 0 V Ignition switch: ON Battery voltage
Is the inspection result normal?
YES
GO TO STEP 8.
NO
GO TO STEP 2 .
- Check the voltage between ECM harness connector and ground under the following conditions.
- CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Disconnect IPDM E/R harness connector.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.
IPDM E/R ECM Continuity Connector Terminal Connector Terminal E15 60 F92 99 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
GO TO STEP 3 .
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between ECM and IPDM E/R
- Loose or poor connection for each connector and harness
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT-II
- Check the continuity between ECM harness connector and IPDM E/R harness connector.
IPDM E/R ECM Continuity Connector Terminal Connector Terminal E15 55 F92 111 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 5 .
- Check the continuity between ECM harness connector and IPDM E/R harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between ECM and IPDM E/R
- Loose or poor connection for each connector and harness
Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK FUSE
- Disconnect 20 A fuse (No. 64) from IPDM E/R.
- Check 20 A fuse for blown.
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Replace 20 A fuse.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness or connectors.
- CHECK THROTTLE CONTROL MOTOR OUTPUT SIGNAL CIRCUIT FOR OPEN OR SHORT
- Turn ignition switch OFF.
- Disconnect electric throttle control actuator harness connector.
- Disconnect ECM harness connector.
- Check the continuity between electric throttle control actuator harness connector and ECM harness connector.
Electric throttle control actuator ECM Continuity Connector Terminal Connector Terminal F66 5 F92 107 Not existed 108 Existed 6 107 Existed 108 Not existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO STEP 9 .
NO
Repair or replace.
- CHECK ELECTRIC THROTTLE CONTROL ACTUATOR VISUALLY
- Remove the intake air duct.
- Check if foreign matter is caught between the throttle valve and the housing.
Is the inspection result normal?
YES
GO TO STEP 10 .
NO
Remove the foreign matter and clean the electric throttle control actuator inside, then perform throttle valve closed position learning. Refer to DESCRIPTION .
- CHECK THROTTLE CONTROL MOTOR
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 11 .
NO
GO TO STEP 12 .
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
Is the inspection result normal?
YES
GO TO STEP 12 .
NO
Repair or replace harness or connectors.
- REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
- Replace malfunction electric throttle control actuator. Refer to REMOVAL AND INSTALLATION .
- Perform SPECIAL REPAIR REQUIREMENT .
INSPECTION END