DTC Detection Logic

NOTE:

If DTC P0015 is displayed with DTC P0078 first perform trouble diagnosis for DTC P0078. Refer to  DTC LOGIC  . 

DTC No. Trouble diagnosis name
(Trouble diagnosis content)
Detecting condition Possible cause
P0015 B camshaft position B1
("B" camshaft position - timing over-retarded bank 1)
During the retarded control of exhaust valve timing control, the angle difference between actual angle and target angle is 13 degrees or more.
  • Crankshaft position sensor
  • Camshaft position sensor
  • Exhaust valve timing control position sensor
  • Exhaust valve timing control solenoid valve
  • Accumulation of debris to the signal pick-up portion of the camshaft
  • Timing chain installation
  • Foreign matter caught in the oil groove for exhaust valve timing control