DTC Detection Logic
|
DTC No. |
CONSULT screen terms |
DTC detecting condition |
||
|
(Trouble diagnosis content) |
Malfunction type |
|||
|
P0130 |
11 |
O2 SENSOR B1 SEN1 (O2 Sensor Circuit Bank 1 Sensor 1) |
CIRCUIT SHORT TO GROUND |
Oxygen sensor 1 (cylinder bank 1) has an electrical malfunction. There is a short circuit to ground. |
|
12 |
CIRCUIT SHORT TO BATTERY |
Oxygen sensor 1 (cylinder bank 1) has an electrical malfunction. There is a short circuit to positive. |
||
|
84 |
SIG BELOW ALLOWABLE RANGE |
Oxygen sensor 1 (cylinder bank 1) has an electrical malfunction. There is a signal below the permissible limit value. |
||