DTC Description: Notes
The Heated Oxygen Sensor 2 has a much longer switching time between rich and lean than the Air Fuel Ratio (A/F) Sensor 1. The oxygen storage capacity of the three way catalyst 1 causes the longer switching time.
MALFUNCTION A
To judge malfunctions of Heated Oxygen Sensor 2, ECM monitors whether the voltage is unusually high during various driving conditions such as fuel cut.
MALFUNCTION B
To judge malfunctions of Heated Oxygen Sensor 2, ECM monitors whether the minimum voltage of Sensor is sufficiently low during various driving conditions such as fuel cut.