How To Set
With CONSULT
Perform "TEMP SET CORRECT" of HVAC work support item.
|
Work support items |
Display (deg. C) |
Display (deg. F) |
|
TEMP SET CORRECT |
3.0 |
6 |
|
2.5 |
5 |
|
|
2.0 |
4 |
|
|
1.5 |
3 |
|
|
1.0 |
2 |
|
|
0.5 |
1 |
|
|
0 (initial status) |
0 (initial status) |
|
|
-0.5 |
-1 |
|
|
-1.0 |
-2 |
|
|
-1.5 |
-3 |
|
|
-2.0 |
-4 |
|
|
-2.5 |
-5 |
|
|
-3.0 |
-6 |
NOTE:
- When -3.0 deg. C (-6 deg. F) is corrected on the temperature setting set as 25.0 deg. C (77 deg. F) the temperature controlled by A/C Auto Amp. is 25.0 deg. C (77 deg. F) -3.0 deg. C (-6 deg. F) = 22.0 deg. C (72 deg. F) and the temperature becomes lower than the temperature setting.
- When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.