Ignition Battery Saver System
Ignition Position [ON]
When all the following conditions are met for 10 minutes, the battery saver system will cut off the power supply (ignition switch position ON -> OFF) to prevent battery discharge.
Ignition Position [ACC]
When all the following conditions are met for 30 minutes, the battery saver system will cut off the power supply (ignition switch position ACC -> OFF) to prevent battery discharge.
- Ignition switch is in the ACC position
- Turn signal lamp is not in operation
- Selector lever is in the P position
Reset Condition of Ignition Battery Saver System
If any of the following conditions are met the battery saver system is released.
- Ignition switch is not in the ACC/ON position.
- Turn signal lamp is operation.
- Selector lever is not in the P position.
NOTE:
The ignition battery saver system can be temporarily disabled, without using CONSULT, to prevent it from functioning when performing trouble diagnosis. Refer to Work Procedure .