Work Procedure
Vehicle specification needs to be written with CONSULT because it is not written after replacing BCM.
Configuration has three functions as follows.
|
Function |
Description |
|
|
Read / Write Configuration |
Before Replace ECU |
|
|
After Replace ECU |
Writes the vehicle configuration with saved data. |
|
|
Manual Configuration |
Writes the vehicle configuration with manual selection. |
|
Automatic setting item: Items which are written in automatically (Setting cannot be changed)
For some models and specifications, the automatic setting item may not be displayed.
- Complete the procedure of "Read / Write Configuration" in order.
- Configuration is different for each vehicle model. Confirm configuration of each vehicle model.
- Never perform "Read / Write Configuration" except for new BCM.
- If you set incorrect "Read / Write Configuration", incidents might occur.
- WRITING MODE SELECTION
CONSULT Configuration
Select "Re/programming, Configuration" of BCM.
When writing saved data
GO TO 2.
When writing manually
GO TO 3.
- PERFORM "AFTER REPLACE ECU" OF "READ / WRITE CONFIGURATION"
CONSULT Configuration
Perform "After Replace ECU" of "Read / Write Configuration".
WORK END
- PERFORM "MANUAL CONFIGURATION"
CONSULT Configuration
- Select "Manual Configuration".
- Identify the correct model and configuration list. Refer to Work Item List .
- Confirm and/or change setting value for each item.CAUTION: Thoroughly read and understand the vehicle specification. ECU control may not operate normally if the setting is not correct.NOTE: If items are not displayed, touch "Next". Refer to Work Item List . for written items and setting value.
- Touch "Next".
- Touch "OK".CAUTION: Make sure to select "OK" even if the indicated configuration of brand new BCM is same as the desirable configuration. If not, configuration which is set automatically by selecting vehicle model cannot be memorized.
- Check that the configuration has been successfully written and touch "End".
GO TO 4.
- OPERATION CHECK
Confirm that each function controlled by BCM operates normally.