Work Procedure
Decel G sensor calibration must be performed when the following operation is performed.
- Removal and installation or replacement of yaw rate/side/decel G sensor
- Replacement of A/T assembly
- Replacement of control valve & TCM
- Replacement of ABS actuator and electric unit (control unit)
CAUTION:
After removing/replacing the yaw rate/side/decal G sensor or replacing the ABS actuator and electric unit (control unit), the decel G sensor of the ABS actuator and electric unit (control unit) must be calibrated first. Refer to Work Procedure
.
- PREPARATION BEFORE CALIBRATION PROCEDURE
- Park the vehicle on a flat road.
- Adjust pressure in all tires to the specified value. Refer to TIRE AIR PRESSURE : Service Data .
GO TO 2.
- PERFORM CALIBRATION
With CONSULT
- Turn ignition switch ON.CAUTION: Never start the engine.
- Select "G SENSOR CALIBRATION" in "Work Support" in "TRANSMISSION".
- Touch "START".CAUTION: Never give any motion to the vehicle during the calibration.
Is "completed" displayed?
YES
GO TO 3.
NO
Perform the calibration again.
- Turn ignition switch ON.
- CHECK DTC
With CONSULT
- Turn ignition switch OFF and wait 10 seconds or more.
- Turn ignition switch ON.
- Select "Self Diagnostic Results" in "ABS".
Is "C1145" or "C1146" detected?
YES
Refer to DTC Index .
NO
WORK END